ISO 23369:2022
p
ISO 23369:2022
84020

Abstract

 Preview

This document specifies:

a)    A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.

b)    A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.

c)    A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 µm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

d)    A test using ISO 121031 A3 medium test dust contaminant and a test fluid.

This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

This document is applicable to three test conditions:

    Base upstream gravimetric level of 3 mg/L;

    Base upstream gravimetric level of 10 mg/L;

    Base upstream gravimetric level of 15 mg/L.


General information 

  •  :  Published
     : 2022-12
  •  : 2
     : 35
  •  : ISO/TC 131/SC 6 Contamination control
  •  :
    23.100.60 Filters, seals and contamination of fluids

Buy this standard

en
Format Language
std 1 145 PDF + ePub
std 2 145 Paper
  • CHF145

Got a question?

Check out our FAQs

Customer care
+41 22 749 08 88

Opening hours:
Monday to Friday - 09:00-12:00, 14:00-17:00 (UTC+1)

Keep up to date with ISO

Sign up to our newsletter for the latest news, views and product information.